Part Number Hot Search : 
4HC163 74HC42 SA9102F 48S03 ADUM1280 FR150G 24C08 2SB1400
Product Description
Full Text Search
 

To Download PS113-00 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 CircuLaser Diode
PS113-00 635nm, 35mW
Description The CircuLaser PS113 is a 0.63 m band, AlGalnP index guided, laser diode with a multiquantum well (MQW) structure. It is suitable as a light source for laser pointers and optical equipment for alignment. Combined with an integrated, internal, beam correcting optic and encased in a hermetic sealed package, this is a high-performance, highly reliable, and long life laser diode. Features
* * * * *
Built-in monitor photodiode Circular, diverging beam, NA approximately 0.11 Diffraction limited wavefront, aberration equal or better than /4 peak to valley 35mW (CW maximum) optical power Standard 5.6 mm form factor Absolute Maximum Ratings (TC=case temperature=25C) *
Item Optical output power LD reverse voltage PD reverse voltage Operating temperature Storage temperature
Symbol PO VR (LD) VR (PD) Topr Tstg
Min -10 -40
Max 35 2 30 +50 +85
Unit mW V V C C
Optical and Electrical Characteristics (TC=case temperature=25C) * Item Optical output power Threshold current Operating current Operating voltage Slope efficiency Lasing wavelength Circularity Beam divergence Off axis angle Monitor current Astigmatism Symbol PO Ith Iop Vop s p IS AS 6 0.05 Min 30 0.4 635 Typ 45 95 2.3 0.6 639 8 0.15 Max 35 65 130 2.8 0.9 642 1.2:1.0 11 3 0.25 0.25 Unit mW mA mA V mW/mA nm ratio deg deg mA waves Po=30mW,VR(PD)=5V PO=30mW PO=30mW
18(mW)/(I(24mW)-I(6mW))
Test Conditions Kink free
PO=30mW PO=30mW PO=30mW, FWHM
* Specifications are subject to change without notice. Each purchased CircuLaser is provided with test data. Please refer to this data before using the CircuLaser.
BSR171 08/01
1537 Centre Pointe Drive Milpitas, CA 95035 TEL (408) 941-6068 FAX (408) 941-6069 Email:info@blueskyresearch.com www.blueskyresearch.com
CircuLaser - Package Detail, Mechanical & Electrical - PS113-00
2.70.2
Handling Care and Precautions for Use of CircuLaser Diodes
1. Absolute Maximum Ratings Do not exceed, even momentarily, the maximum ratings (see page 1, table). When a CircuLaser diode is driven in excess of it's maximum ratings, it can cause at minimum a considerable reduction in reliability, and potentially instantaneous failure. a. CircuLaser diodes may be damaged by surge currents generated at power on-off operation. Check on the transient characteristics of the power supply to make sure that such surges do not exceed the maximum ratings. b. The maximum ratings are specified for a case temperature of 25C. Designs should be made to work well within this temperature range. As the case temperature goes up, power dissipation as well as maximum light output power is reduced. 2. Soldering Conditions Maximum solder-tip temperature is 260C and soldering time must be within 3.0 seconds. A minimum solder clearance of 1.6mm should be maintained from the root of the lead. 3. Prevention of Breakdown due to Static Electricity CircuLaser diodes may be adversely affected by static electricity and surge currents and, consequently, cause breakdown of the diode and reduction of reliability unless the following precautions are taken: a. Power supplies, installation and measuring equipment should be grounded. A noise filter or noise-cut transformer should be provided on any power supply inputs. b. Anyone working with a CircuLaser diode should be grounded through high resistance (500 K Ohm - 1M Ohm) by means of a ground strap and wrist band (for example). c. Soldering irons should be grounded to protect laser diodes from voltage leaks. d. During operation of the CircuLaser diode, working clothes, hats, and shoes should be static-protected. Cotton-based clothing is preferred. e. Any container for carriage and storage should be static-protected. f. Avoid using laser diodes in an environment where high frequency surge currents may be generated by an inductive electric field (such as a fluorescent lamp). These fields can also cause breakdown or deterioration of the laser diode. 4. Package Handling a. The laser diode package should not be cut off, reworked, or deformed. Do not hold the cap of the CircuLaser diode tightly, otherwise it may induce cracks or damage to the window glass. b. Do not touch the surface of the window glass. Any scratch or contamination may result in reduction of optical characteristics. c. Remove small contaminates on the surface softly using a cotton tip stick with a small amount of methyl alcohol. 5. Safety The output light from laser diodes is harmful to a human body even if it is invisible. Avoid looking at the output light of a CircuLaser diode directly, or even indirectly through a lens during operation. Observance of operation should be through an infrared TV camera or related equipment. Refer to IEC 825-1 and 21 CFR 1040.10-1040.11 as a radiation safety standard for laser products.
BSR171 08/01
1537 Centre Pointe Drive Milpitas, CA 95035 TEL (408) 941-6068 FAX (408) 941-6069 Email:info@blueskyresearch.com www.blueskyresearch.com


▲Up To Search▲   

 
Price & Availability of PS113-00

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X